Please note that the colour of the cables may differ from property to property so the colour of the cables used in this document may not be an indication of exactly which cable is needed but we will be using the diagram as reference here;
To connect live power to both dimmer switches you will first need to ensure that the black cable with the red flash from the L1 terminal is connected to the terminal marked ‘L’ on the lightwave switch. A further link cable (yellow with red flash in diagram) will be needed to provide power to the live terminal on the secondary switch, this will act as a link cable between the 2 live terminals.
The switch live cable (red cable connected to L2 from cable C) will be connected to our terminal marked 'X' and a further link cable will be needed to connect the secondary 'X' terminal to the first switch, this is demonstrated as the blue cable with the red flash in the diagram provided. Lastly the connecting red cable connected to COM will need to be used to link the terminals on our switches marked 'S' together to provide the switch with a signal cable if this is a Connect Series switch set up. If you have Smart Series devices then this cable will become redundant as the connection between the switches will be achieved via the automation process with in the app.
Comments