Once the dimmer has been installed, lamps added to the circuit and the power switched on, it will enter calibration mode. This mode calculates the appropriate settings and dimming range to maximise compatibility with the lamps being used on the circuit.
Automatic Calibration
If the dimmer has not previously been calibrated, it will automatically calibrate itself to the lamps detected on the circuit after 5 seconds. If the dimmer has been calibrated previously, these settings will be restored unless the on button is pressed within 5 seconds to overwrite them with a new calibration (recommended if lamps are changed). Auto calibration is denoted by flashing green LEDs.
Manual Calibration
Manual calibration should be used in the event of persistent lamp flicker or instability. By pressing the off button within 5 seconds of introducing power to the dimmer, it will initiate manual calibration. This is initially denoted by flashing green and red LEDs. Pressing the on and off buttons now will extend or shorten the lower dimming limit. Pressing both buttons together will save the setting. Next, flashing green and blue LEDs denote that pressing the on and off buttons will now alter the upper limit. Press both buttons to save this setting.
The Lightwave Smart Series dimmers can be manually calibrated to suit your lights. The video below highlights how this can be done from the app and it applies to different types of lamps, such as LED or incandescent.